LMR Coaxial Cable Power Ratings

Maximum Power Rating – Kilowatts(KW) at MHz

LMR Cable 30 50 150 220 450 900 1500 1800 2000 2500
100A .23 .18 .10 .08 .06 .05 .04 .03 .02 .01
195/HPF195 .84 .68 .39 .32 .22 .15 .12 .11 .10 .09
200 1.02 .79 .45 .37 .26 .18 .14 .13 .12 .10
240/HPF240 1.49 1.15 .66 .54 .38 .26 .20 .18 .17 .15
300 2.1 1.6 .92 .76 .52 .36 .28 .25 .24 .21
400/3810 3.3 2.6 1.5 1.2 .83 .58 .44 .40 .37 .33
400UF 3.3 2.6 1.5 1.2 .83 .58 .44 .40 .37 .33
500 4.4 3.4 1.9 1.6 1.1 .75 .57 .52 .49 .43
600 5.5 4.2 2.4 2.0 1.35 .93 .70 .63 .59 .52
600UF 5.5 4.2 2.4 2.0 1.35 .93 .70 .63 .59 .52
900 8.9 6.9 3.9 3.2 2.2 1.5 1.1 1.0 1.0 .9
1200 12.6 9.7 5.5 4.5 3.1 2.1 1.6 1.4 1.3 1.2
1700 20.3 15.6 8.7 7.1 4.8 3.3 2.4 2.2 2.0 1.8